WX-101W Operating Description: Factory settings: press and hold the set button to power, 3 seconds after the release button to restore the factory settings!
Control mode setting: Press the `SET` button once to display F-1, then press the `SET` button once to enter the F-1 menu, then press the `plus` button to display [HH] for heating control mode, `Button to display [CC] for the cooling control mode, select a good press the set button to save and exit!
temperature setting: in the display of the current temperature interface directly press the `plus` or `minus` button to set the required control temperature point, set the time after the `set` button to save and exit!
Press the `Add` button to adjust the function number. When the F-1 is displayed, press the `plus` button to display the F (1) key. -2, then press the `set` button once to enter the F-2 function, that is, the hysteresis parameter adjustment interface, directly press the `plus` or `minus` button to adjust the hysteresis, hysteresis means start temperature and stop The temperature difference;
if you want to control the heating If the control temperature set 30 degrees, the hysteresis is set to 2, then the current temperature is more than 30 degrees relay disconnect, less than 28 degrees relay closed, the difference is 2! Refrigeration control is the opposite control state!
temperature correction settings: adjust the function number for the F-3 display, press the `set` button to enter the F-3 parameter adjustment interface, adjust the range of -5.0 ~ 5.0, when the temperature is not accurate, this function can be temperature correction , If the measured current temperature is higher than the actual temperature of 0.5 degrees, adjust the calibration parameter is -0.5, press the `set key` to save!
delay start time setting: when the start after the start to the next start to meet the set time before they can start, usually for the cooling control mode to protect the compressor, th

Bővebb leírás

-1 / 1 / Gyorsan Fogyó termék

279 Ft‎

-75%

1 116 Ft‎

Egyéb infó

WX-101W temperature control board temperature control switch digital thermo O9O3

WX-101W Operating Description: Factory settings: press and hold the set button to power, 3 seconds after the release button to restore the factory settings!
Control mode setting: Press the `SET` button once to display F-1, then press the `SET` button once to enter the F-1 menu, then press the `plus` button to display [HH] for heating control mode, `Button to display [CC] for the cooling control mode, select a good press the set button to save and exit!
temperature setting: in the display of the current temperature interface directly press the `plus` or `minus` button to set the required control temperature point, set the time after the `set` button to save and exit!
Press the `Add` button to adjust the function number. When the F-1 is displayed, press the `plus` button to display the F (1) key. -2, then press the `set` button once to enter the F-2 function, that is, the hysteresis parameter adjustment interface, directly press the `plus` or `minus` button to adjust the hysteresis, hysteresis means start temperature and stop The temperature difference;
if you want to control the heating If the control temperature set 30 degrees, the hysteresis is set to 2, then the current temperature is more than 30 degrees relay disconnect, less than 28 degrees relay closed, the difference is 2! Refrigeration control is the opposite control state!
temperature correction settings: adjust the function number for the F-3 display, press the `set` button to enter the F-3 parameter adjustment interface, adjust the range of -5.0 ~ 5.0, when the temperature is not accurate, this function can be temperature correction , If the measured current temperature is higher than the actual temperature of 0.5 degrees, adjust the calibration parameter is -0.5, press the `set key` to save!
delay start time setting: when the start after the start to the next start to meet the set time before they can start, usually for the cooling control mode to protect the compressor, th